DMEs WZD duplex volume controlled water softener

DMEs WZD duplex volume controlled water softener

The device is of continuous operation, so it is capable of providing soft water during regeneration, too. Suggested in case of fluctuating water withdrawal. The device starts regeneration cycle depending on water quantity having passed through: it means the system is volume controlled. (Regeneration starts automatically after the exhaustion of the resin column).

Technical data

Equipment
data
Type - DMEa ZGE
01 006002 012003 020004 032005 0400 06 050007 060008 0800 09 100010 120015 120020 140025 2000
Nominal flow
rate [m3/h]
12 3 4 910 15 20 25 
Capacity
[m3xdH]
60 120 200 320 400 500 600 800 1000 1200 1200 1400 2000 
Operating pressure [bar]2.5 - 8.5 
Inlet water temperature
[°C]
1 - 43 
Ambient temperature 
[°C]
1 - 43 
Salt cons./
regeneration [kg]
 10 1620 25 30 40 50 60 60 70 100 
Dimensions 
(HxWxD) [mm] 

1100 x 1300 x 500 

1100 x 1300 x 500 1300 x 1300 x 5001600 x 1400 x 570 1850 x 1800 x 850 1850 x 
2000 x 850 
2000 x 2100 x 850 1850

2500 x 
1000 
 1850 x 2500 x
950
1850 
x 2650 x 1200 
2100
x
3400
x
1100 
2100
x
3600
x
1200 
2500
x
4300
x
1200 
Operating weight [kg]160 190 240 410 610 660  7801100 1290 1600 2500 3100 4000
Water inlet/outlet connection1" BSP female 1 1/2" BSP female 2" BSP female 
Brine connection  nozzle for 3/8" polyethylene (PE) hosenozzle for 1/2" polyethylene (PE) hose 
Control valve drain connection nozzle for d13x19 PVC hosenozzle for d16x22 PVC hose 
Brine tank overflow connection nozzle for d13x19 PVC hose nozzle for d25x34 PVC hose 

Print this pageForward this page