Hydracine has a hydrogen binding effect, it is vapour volatile and encourages the formation of protectory films on steel surfaces. As hydracine is carcinogenic, its decanting and metering systems must be gas-proof so that no hydracine vapours can escape. Our systems come up to these requirements.
Functions
- Delivering of the hydrazine from containers into dosing tank
- Generation of a hydracine solution
- Dosing of hydracine solution into the application
Bodywork
- Transfer pump
- Admeasuring device with activated carbon filter
- Metering reservoir (gas proof)
- Manual agitator (gas proof)
- Metering pump with suction lance
Advantages
- Gas-proof design
- Exact metering
- Protection of the environment
Application areas
- Vapour circuits
- Power stations
Device types
The plants are available in various sizes with metering reservoirs of 140, 250 and 500 litres. |