Germany
Quicksearch
Home Sitemap Downloads Contact Imprint Deutsch  ProMinent Worldwide
ApplicationsIndustry SolutionsProductsServiceInfo-CenterCompany
Newsletter
Home > Products > Measuring, Control, and Sensor Technology > Bromine > Controllers & Transmitters
Products
Overview
New Products
Storage Tanks
Chemical Transfer Pumps
Disinfection and Oxidation Systems
Metering Pumps
Dosing Systems
Filters & Softeners
Measuring, Control, and Sensor Technology
pH
Redox
Chlorine
Conductivity
Chlorine Dioxide
Chlorite
Bromine
Sensors
Housings
Controllers & Transmitters
Portable Measuring Devices
Ozone
Hydrogene Peroxide
Peracetic Acid
Fluoride
Dissolved Oxygen
Temperature
Panel-Mounted Measuring and Control Stations
Membrane Filtration
Accessories
References
DULCOMETER® D1C Single Channel Controller

DULCOMETER® D1C Single Channel Controller


Single channel controller with control characteristics P and PID, measuring variables pH, Redox, Chlorine, Bromine, Chlorine Dioxide, Chlorite, Ozone, inductive and conductive conductivity, Fluoride, H2o2, Peracetic Acid, Temperature and Standard Signal.

The single channel controller DULCOMETER® D1C is a measuring and control device based on microprocessor technology that grants highest process safety with a comprehensive application spectrum. The controller is configurable and can thus individually be adjusted to your requirements. This is not only valid for its type of control but also for its construction type (wall mounting or panel mounting) and many more parameters. You select what you need for your regulation task and only pay for that.

Advantages

  • Universally implementable, as many measuring values controllable: beside pH, Redox, conductivity and Chlorine, also Dissolved Oxygen, Fluoride, Bromine, Chlorine Dioxide, Chlorite, Ozone, Hydrogen Peroxyde and Peracetic Acid.
  • Ideal adjustment to process requirements thanks to various stages of extension
  • Seamless integration into your process technology: variable installation possibilities for the sensors and large number of control possibilities for metering devices.
  • Optimized process flows through special functions such as disturbance feedforward, pH compensation for Chlorine, base load dosing and many limit value functions.
  • Safety: limit value monitoring with standardized dosing time restrictions.
  • Easy and clear user guidance with text indicator on big graphic display in 16 languages.
  • Large, easily readable graphic display for measuring values, correction values and information.

Features

  • Limit value control with standardized control variable shutoff
  • Disturbance insensitive probe connection in dual wire technology
  • 2 signal outputs 0/4 - 20 mA galvanically separated
  • Various construction types for wall and panel mounting
  • 1 digital input for "break" and "error" measuring water
  • Disturbance signal processing as digital or analogue signal
  • 2 timers as cleaning contact or for shock dosing
  • Additive basic load dosing
  • Bidirectional control
  • Neutral zone control
  • Temperature compensation for pH, conductivity and Chlorine Dioxide process measuring
  • pH correction for Chlorine
  • Adjustable access code

Technical Data

Measurand Value
Accuracy 0,5 % of measuring range
Correction variable Temperature over Pt 100 or transmitter 4...20 mA
Correction range 0...100°C
Disturbance signals Adder/multiplier
Control characteristic P, PI, PD, PID
Control

Bidirectional control

Dead zone control

Additive basic load

manually adjusted control variable for test purposes

Control output

2 reed contacts (pulse rate output)

2 power relays (pulse length) or

1 output for servomotor with report function

2 analogue outputs (0/4...20 mA)

Analogue output

2 analogue outputs (0/4...20 mA) galvanically separated, max. load 600 Ω (2nd output 400 Ω). Adjustable direction measurement, correction and control variable.

Alarm relay 250V ~3 A, 700 VA, changeover contact
Power supply 24 V AC/DC / 100 V~ / 115 V~ / 200 V~ /230 V~ ±10%
Protection class

Wall mounted: IP 65

Control panel version: IP 54

Ambient temperature

Wall mounted: -5...40°C (not precipitating)

Control panel version: 0...40 °C (not precipitating)

Dimensions in mm (HxWxD)

Control panel version: 96 x 96 x 140

Wall mounted: 189 x 200 x 76

Measurand

Measuring and Control Range Resolution Sensor input
pH 0 - 14 0,01pH Input resistance > 1012 W
Clamp standard signal 0/4...20 mA
Redox -1000 - +1000 mV 1 mV

Input resistance > 5 x 10 11 W 
Clamp standard signal 0/4...20 mA

Chlorine

0,005 - 0,500 ppm
0,05 - 2,00 ppm
0,05 - 5,00 ppm
0,05 - 10,00 ppm
0,05 - 20,00 ppm
0,05 - 50,00 ppm
0,05 - 100,00 ppm

0,001 ppm
0,01 ppm

Clamp standard signal 0/4...20 mA

 

Bromine 0,02 - 2,00 ppm
0,1 - 10,0 ppm
0,01 ppm Clamp standard signal 0/4...20 mA
Conductive conductivity 0 - 20 µS/cm
0 - 200 µS/cm
0 - 2 mS/cm
0 - 200 mS/cm
0,001 µS/cm Clamp conductive conductivity
Inductive conductivity

0 - 200 µS/cm
0 - 2 mS/cm
0 - 200 mS/cm
0 - 2000 mS/cm

0,01 µS/cm Clamp inductive conductivity
Chlorine dioxide

0,005 - 0,500 ppm
0,05 - 2,00 ppm
0,05 - 10,00 ppm
0,05 - 20,00 ppm

0,001 ppm      
0,01 ppm
Clamp standard signal 0/4...20 mA
Chlorite

0,005 - 0,500 ppm
0,05 - 2,00 ppm

0,001 ppm     
0,01 pmm
Clamp standard signal 0/4...20 mA
Ozone 0,05 - 2 ppm 0,01 ppm Clamp standard signal 0/4...20 mA
Fluoride 0,05 - 10 mg/l 0,01 ppm Clamp standard signal 0/4...20 mA
Dissolved oxygen 0,1 - 10 mg/l            
0,1 - 20 mg/l
0,001 ppm      
0,01 ppm
Clamp standard signal 0/4...20 mA

Hydrogen peroxide

1 - 20 ppm
20 - 200 ppm
20 - 2000 ppm
0,01 - 1,00 %

0,01 ppm


0,01 %
Clamp standard signal 0/4...20 mA
Peracetic acid

1 - 20 ppm
20 - 200 ppm
20 - 2000 ppm
0,01 - 1,00 %

0,01 ppm


0,01 %
Clamp standard signal 0/4...20 mA
Temperature

0 - 100 °C

0,1 °C

Clamp Pt 100 / Pt 1000

Clamp standard signal 0/4...20 mA

Analogue signal 0/4...20 mA Clamp standard signal 0/4...20 mA

ProMinent offers DULCOMETER® measurement and control devices, DULCOTEST® sensor technology as well as ProMinent metering pumps for the creation of complete control circuits. Measuring, Control, Dosing and Recording all from one hand and optimally inter-adjusted.

Infos / Downloads

Operating Instructions - DULCOMETER® D1C - Part 1: Mounting and installation instructions for wall-mounted and control panel-mounted devices [1.58 MB]

Operating Instructions - DULCOMETER® D1C - Part 2:Adjustment and Operation, Measured Variable pH [0.42 MB]

Operating instructions - DULCOMETER® D1C - Part 2: Measured Variable Redox/ORP [0.38 MB]

Operating Instructions - DULCOMETER® D1C - Part 2: Adjustment and Operation, Measured Variable Conductive Conductivity [0.36 MB]

Operating Instructions - DULCOMETER® D1C - Part 2 Adjustment and Operation: Measured Variable Chlorine [0.42 MB]

Operating Instructions - DULCOMETER® D1C - Part 2: Adjustment and Operation, Measured variable chlorine dioxide [0.41 MB]

Operating instructions - DULCOMETER® D1C Part 2: Measured Variable Oxygen [0.37 MB]

Operating Instructions - DULCOMETER® D1C - Part 2: Measured variable bromine [0.36 MB]

Operating Instructions - DULCOMETER® D1C - Part 2: Adjustment and Operation, Measured Variable Ozone [0.39 MB]

Operating Instructions - DULCOMETER® D1C - Part 2: Adjustment and Operation, Measured Variable Fluoride [0.39 MB]

Documentation of controller settings, type D1Ca [0.04 MB]

Documents in other languages can be found here
Contact Us!
Advice, Enquiries and Service
Request for Information Material
Your Contacts Worldwide
Info / Downloads
downloads
© 2009 Copyright ProMinent. All rights reserved.