Germany
Quicksearch
Home Sitemap Downloads Contact Imprint Deutsch  ProMinent Worldwide
ApplicationsIndustry SolutionsProductsServiceInfo-CenterCompany
Newsletter
Home > Products > Measuring, Control, and Sensor Technology > Ozone > Portable Measuring Devices
Products
Overview
New Products
Storage Tanks
Chemical Transfer Pumps
Disinfection and Oxidation Systems
Metering Pumps
Dosing Systems
Filters & Softeners
Measuring, Control, and Sensor Technology
pH
Redox
Chlorine
Conductivity
Chlorine Dioxide
Chlorite
Bromine
Ozone
Sensors
Housings
Controllers & Transmitters
Portable Measuring Devices
Hydrogene Peroxide
Peracetic Acid
Fluoride
Dissolved Oxygen
Temperature
Panel-Mounted Measuring and Control Stations
Membrane Filtration
Accessories
References
Photometer

Photometer


Microprocessor-controlled Photometer DT1, DT2B, DT3 and DT4 serve to calibrate amperometric and fluoride measuring systems by comparison measurement. They are preassigned to defined verification procedures and include various measurand. With few expenditure of time precise and reproducible analysis results can be achieved.

One of its main advantages is its operation comfort and its safe handling thanks to ergonomic and compact design. Luminous source are LEDs with high long-run constancy and monochromatic light spending at low power input.

The measuring principle is the photometric method, e.g. the DPD method using fluid reagants according to the German standard DIN 38 408. The big advantage of Photometers against comparators: the light conditions to measure the sample are invariable, this granting higher accuracy and minimizing the chance of subjective errors.

Application Areas

  • Swimming pool water treatment
  • Food technology
  • Drinking water treatment
  • Cooling water

Features

  • Portable compact Photometer
  • Automatic zero calibration
  • Short measuring cyclus (ca. 3 seconds)
  • Big digital display
  • Microprocessor technology
  • Long-run constant LEDs  
  • Test fluid appropriateness (calibratable)
  • Use of long-time stable Lovibond reagent tablets or container vessel tests
  • Compact ergonomic design
  • Complete Photometer equipment in one portable bag
  • Automatic cutoff
  • Photometers supplied with accessories, container vessels and reagents

Technical Data

Measurand Value
Power supply 9V Block for 600 measurement cycles à 4 min.
Measuring tolerance

dependent on measuring value and measuring method

Keyboard material Polycarbonate foil
Housing material Polycarbonate
Ambient temperature 5...40°C
Relative humidity 30...90% (not precipitable)
Dimensions (HxWxD in mm) 190 x 110 x 55
Weight ca. 0,4 kg

Measurand DT1 DT2B DT3 DT4
free Chlorine (DPD1) in ppm 0,05...6,00 0,05...6,00

-

0,05...6,00
compound Chlorine (DPD1 + DPD3) in ppm 0,05...6,00 0,05...6,00

-

0,05...6,00
compound Chlorine (DPD4) in ppm 0,05...6,00 0,05...6,00

-

0,05...6,00

Bromine (DPD1 at DBDMH, DPD4 at BCDMH) in ppm

0,1...13,00

-

-

-

Ozone in ppm 0,03...4,00

-

-

-

Chlorine dioxide in ppm

0,1...11

0,05...11,0

-

0,05...11,00
Chlorite in ppm

-

-

-

0,03...2,5
Hydrogen peroxide in ppm

-

-

1...50

40...500

-

Cyanuric acid in ppm 1...80

-

-

-

pH (Phenole red) 6,5...8,4

-

-

-

Fluoride in ppm

-

0,05...2,00

-

-

Infos / Downloads

Operating instructions - DULCOTEST® DT1 Photometer [0.16 MB]

Operating instructions - Photometer DT 2 B [0.04 MB]

Operating instructions - DULCOTEST® DT3 Photometer [0.2 MB]

Operating instructions - DULCOTEST® DT4 Photometer [0.23 MB]

Documents in other languages can be found here
Contact Us!
Advice, Enquiries and Service
Request for Information Material
Your Contacts Worldwide
Info / Downloads
downloads
Related Applications

Cooling Water Treatment

Related Industry Solutions

Complete solutions for the beverage industry

Potable Water Treatment

© 2009 Copyright ProMinent. All rights reserved.