Chlorine Dioxide System Bello Zon® CDKc

8 – 12,000 g/h chlorine dioxide. Max. flow rate at 0.2 ppm ClO2 metering is 60,000 m3/h

Chlorine dioxide system for continuous production, metering and monitoring of chlorine dioxide with concentrated chemicals. Bello Zon® CDKc is a ready-to-use convenient system with integrated intrinsically safe pre-dilution station.

Product description

Bello Zon® CDKc is a deluxe system, persuading customers with its safe handling of chemicals.

This chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary system includes an intrinsically safe pre-dilution station for concentrated hydrochloric acid. The consumption of hydrochloric acid can therefore be adapted on site to the individual operating conditions. Savings of up to a quarter of the hydrochloric acid volume are possible. The special reactor concept generates chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary safely and simply with maximum output. Food-compatible PVDF is used instead of PVC generally used in the industry. This results in improved operating safety and reliability and improved purity of the chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary generated. The central system controller manages the precise production of the chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary. All parameters relevant for water treatment are recorded and logged. The stroke lengths of ProMinent® metering pumps are monitored online. This rules out hazardous operating statuses owing to incorrect operation with regard to pump stroke length adjustment. The precise production of chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary is managed by the central system control. Chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary, chlorite, pH or redox potential sensors DULCOTEST® are directly connected to the two mA inputs. The chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary in the treated water, as well as its main by-product chlorite, is thus monitored and documented online. The chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary concentrations in the water can be adjusted automatically depending on the measurement using the integrated PID controller. The integrated data logger documents all status messages and measured values, which the screen writer then visualises on the clear colour display. The systems meet all the requirements of DVGW data sheets W 224 and W 624, with regard to construction and operation, and are intended for operation with concentrated chemicals (24.5% NaCIO2) and acid (25-36% HCl).

Your benefits

  • Cost saving through minimal acid consumption
  • Cost-effective operation by the use of inexpensive concentrated output chemicals
  • Efficient operation, thanks to production, metering and monitoring of ClO2 with just one system
  • Maximum operating safety and purity of the CIO2 produced through the use of PVDF reactors
  • Integrated measuring and control technology
  • Perfect quality management, thanks to integrated storage of all operating parameters and measured values

Field of application

  • Municipal potable water and waste water treatment
  • Industrial process and cooling water
    1 2 3 4

    Technical Details

    Power supply

    • 100-230 V, 50/60 Hz

    Inputs

    • 2 freely configurable analogue inputs (0/4-20 mA)
    • 7 digital inputs for monitoring
    • 1 digital input for contact water meter 0.25 – 20 Hz
    • 1 frequency input for water meter 10 – 10,000 Hz

    Outputs

    • 1 operating signal relay
    • 1 alarm signal relay
    • 1 warning signal relay
    • Mains output for control of the bypass pump
    • 1 freely configurable analogue output (0/4-20 mA)
    • 1 +5 V voltage output as supply voltage for water meter with Hall sensor

    Operating substances

    • 24.5% sodium chlorite, purity as per EN 938
    • Hydrochloric acid 25 – 36% purity according to EN 939
    • Particle-free water

    Degree of protection

    • IP 65

    Technical Data

    Type 1)Chlorine dioxide dosing capacity* 1)Max. operating pressure**Operating temp.Connection dimensions of chlorite and acid metering pumpsDimensions of the bypass connector
     min.-max./hourmin./day    
    g/hg/d bar°CDN
    CDKc 1508-15056810–406x425
    CDKc 40020-400140810–408x525
    CDKc 90045-900300810–408x532
    CDKc 2000100-2,000700510–408x540
    CDKc 2800140-2,800700515–408x540
    CDKc 7300365-7,3001,750315–40DN 1040
    CDKc 12000600-12,0001,750218–40DN 1040
    Type 1)Dimensions*** H x W x D (mm)Weight***Power consumption (max.) ****Power uptake
       230 V115 V 
    mmkg A A W
    CDKc 1501,380 x 880 x 320550.71.2130
    CDKc 4001,650 x 880 x 445800.91.2180
    CDKc 9001,920 x 920 x 510951.42.5250
    CDKc 20001,880 x 1,320 x 5701602.23.5410
    CDKc 28001,880 x 1,320 x 5701602.23.5410
    CDKc 73002,250 x 1,850 x 4601755.56.4640
    CDKc 120002,250 x 1,850 x 4601805.56.4640
    *The metering figures relate to 5 or 2 bar back pressure and an ambient temperature of 20 °C. The minimum capacity/per hour is based on the fact that when the system is operating at below 5% of the nominal power, continuous metering is no longer possible, due to the correspondingly low pumping frequency of the metering pumps. When systems are not operating continuously, the reactor contents must be changed at least twice daily. The system should not, therefore, be operated below the stated minimum capacity/day.
    **At 35 °C ambient temperature
    ***Without bypass pump, flushing valve and water supply line
    ****230 V figure with bypass pump (CDKc 150-900), 115 V figures without bypass pump
    1)Subject to technical and design changes.

    Dimensions of the pre-dilution unit (H x W x D) for CDKc 150 - 12,000: 1,200 x 900 x 300 mm

    Downloads for Chlorine Dioxide System Bello Zon® CDKc

    load more of

    Overview

    Bello Zon® CDKc is a deluxe system, persuading customers with its safe handling of chemicals.

    This chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary system includes an intrinsically safe pre-dilution station for concentrated hydrochloric acid. The consumption of hydrochloric acid can therefore be adapted on site to the individual operating conditions. Savings of up to a quarter of the hydrochloric acid volume are possible. The special reactor concept generates chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary safely and simply with maximum output. Food-compatible PVDF is used instead of PVC generally used in the industry. This results in improved operating safety and reliability and improved purity of the chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary generated. The central system controller manages the precise production of the chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary. All parameters relevant for water treatment are recorded and logged. The stroke lengths of ProMinent® metering pumps are monitored online. This rules out hazardous operating statuses owing to incorrect operation with regard to pump stroke length adjustment. The precise production of chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary is managed by the central system control. Chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary, chlorite, pH or redox potential sensors DULCOTEST® are directly connected to the two mA inputs. The chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary in the treated water, as well as its main by-product chlorite, is thus monitored and documented online. The chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary concentrations in the water can be adjusted automatically depending on the measurement using the integrated PID controller. The integrated data logger documents all status messages and measured values, which the screen writer then visualises on the clear colour display. The systems meet all the requirements of DVGW data sheets W 224 and W 624, with regard to construction and operation, and are intended for operation with concentrated chemicals (24.5% NaCIO2) and acid (25-36% HCl).

    Your benefits

    • Cost saving through minimal acid consumption
    • Cost-effective operation by the use of inexpensive concentrated output chemicals
    • Efficient operation, thanks to production, metering and monitoring of ClO2 with just one system
    • Maximum operating safety and purity of the CIO2 produced through the use of PVDF reactors
    • Integrated measuring and control technology
    • Perfect quality management, thanks to integrated storage of all operating parameters and measured values

    Application

    Technical Data

    Downloads

    Contact us

    Ralf Kiermaier

    Vice President Sales and Marketing, ProMinent GmbH

    Save contact

    »Please send us your request! We will contact you shortly.«

    +49 6221 842 0  Send request   

    Close Form

    Your Request

    Personal Information


    Further product +
    Attachment
    Upload Next file

    Personal Information


    Please fill in all mandatory fields.
    *Mandatory fields

    Check and Send


    Personal Information:
    Salutation
    Title
    Last name  
    First name  
    Company
    Customer ID
    E-mail address
    Phone
    Street
    House no.
    City  
    Country
    Callback Yes

    Back

    Matching Products

    1 2