Hydraulic Diaphragm Metering Pump ORLITA MF
Capacity range of single-head pump: 0 – 14,000 l/h; 450 – 30 bar
The hydraulic diaphragm metering pump ORLITA MF offers reliable dosing rates even under high pressure and has a modular construction, making it highly versatile. Thanks to its modular design, this pump is tailored to meet your requirements even at very high pump capacities.
Product description
Reliable capacity even at high-pressure
ORLITA MF hydraulic diaphragm metering pumps (MFS 35 to MFS 1400) with a stroke length of 15 to 60 mm provide a capacity ranging from 0 to 14,000 l/h at 450 – 30 bar. A wide range of drive versions is available, including some for use in Zone 1 or Zone 2 areas at risk from explosion with ATEX certification. The ORLITA MF product range is designed to comply with API 675. Its modular construction permits the free combination of drive units, drives and dosing heads, producing a pump for a range of different feed rates and media operating at different working pressures.
Your benefits
Excellent process safety and reliability:
- PTFE double diaphragm with integrated diaphragm rupture warning system ensures precise and low-wear operation despite high pressures
- The product chamber is hermetically separated from the hydraulic part
- Integrated hydraulic relief valve and automatic bleed valve for the hydraulic chamber
- Wear-free, valveless enforced anti-cavitation of the hydraulic leakage guarantees optimum dosing precision
- Cone valves for use as suction and/or discharge valves with minimal wear, good self-cleaning and low pressure loss (NPSHR)
Excellent flexibility:
- The modular construction allows a wide range of uses. In multiple pump systems it is possible to combine up to 6 metering units, even with different pump capacities. In single pumps the drive arrangement may be either vertical or horizontal.
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Oil/ gas production (onshore/offshore)
- Refineries
- Chemical/Petrochemical industry
- Pharmaceuticals & cosmetics
- Food production
- Packaging industry (bottling pumps)
Technical Details
- MfS 35 (MF2a) – stroke length: 0-20 mm, rod force: 3500 N
- MfS 600 (MF5b) – stroke length: 0-40 mm, rod force: 40,000 N
- MfS 1400 (MF6a) – stroke length: 0-60 mm, rod force: 60,000 N
- Stroke length adjustment range: 0 – 100% in operation and idle
- Stroke length adjustment: manually using manual adjustment wheel and scaled display (optionally with electric actuator or control drive)
- Metering reproducibility is better than ± 1% within the 10 – 100% stroke length range under defined conditions and with correct installation (API 675)
- PTFE multi-layer diaphragm with electrical diaphragm rupture warning/signalling system via a contact
- Integrated hydraulic relief and bleed valve
- Wetted materials: Stainless steel, special designs are available on request
- A wide range of power end versions is available: Three-phase standard AC motors, motors for use in areas at risk from explosion and different flange designs for use in customer-specific motors
- Degree of protection: IP 55
- Temperature range - 40 °C to + 150 °C
- Suction lift up to 8 m
- Design in compliance with API 675 among others
Actuation of ORLITA MF, MH, PS, DR
Control drive consisting of an actuator with servo motor and integral servo controller for stroke length adjustment via a standard signal. Standard current input 0/4 – 20 mA, corresponds to stroke length 0 – 100%, switch-over for manual/automatic operation; key switch for stroke adjustment in manual mode, mechanical position display of actual stroke length value output 0/4 – 20 mA for remote display. Control drives can also be designed with bus systems, like HART, PROFIBUS®, Fieldbus Foundation ...
Variable speed motors with integrated frequency converter (identity code specification V)
Power supply 1 ph 230 V, 50/60 Hz (up to 3 kW). Externally controllable with 0/4 - 20 mA.
The following functions are integrated in the terminal box cover:
- Start/stop switch
- Switch for manual/external operation
- Potentiometer for speed control in manual mode
Speed controllers with frequency converter (identity code specification Z)
The frequency converter is accommodated in an IP 55-rated protective housing with integral control unit and main switch, suitable for max. 0.37/0.75 kW motor capacity.
Externally controllable with 0/4 - 20 mA or 0 - 10 V corresponding to 0 - 50 (60) Hz output frequency.
Integrated control unit with versatile functions, such as switching between external/internal control; frequency input using arrow keys with internal control, multilingual fault message display etc. and motor temperature monitoring (thermistor protection).
The speed controller assembly consists of a frequency converter and a variable-speed motor.
Technical data for ORLITA MFS 35 single head pump 50 Hz
Plunger Ø | Theor. stroke volume | Theoretical pump capacity in l/h at strokes/min | Max. pressure | Efficiency | Standard type of valve | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
36 | 58 | 73 | 91 | 112 | 145 | 207 | ||||||
mm | ml/stroke | l/h | l/h | l/h | l/h | l/h | l/h | l/h | bar | At 100 % pressure | At 50 % pressure | |
7 | 0.77 | 1.7 | 2.7 | 3.3 | 4.2 | 5.2 | 6.7 | 9.6 | 400 | 0.50 | 0.70 | DN 3 |
8 | 1.01 | 2.2 | 3.5 | 4.4 | 5.5 | 6.7 | 8.7 | 12.5 | 400 | 0.50 | 0.70 | DN 3 |
10 | 1.57 | 3.4 | 5.5 | 6.8 | 8.5 | 10.5 | 13.7 | 19.5 | 400 | 0.50 | 0.70 | DN 6 |
12 | 2.26 | 4.9 | 7.9 | 9.8 | 12.3 | 15.1 | 19.7 | 28.1 | 309 | 0.79 | 0.85 | DN 6 |
14 | 3.08 | 6.7 | 10.7 | 13.4 | 16.7 | 20.6 | 26.8 | 38.3 | 227 | 0.81 | 0.85 | DN 6 |
16 | 4.02 | 8.7 | 14.0 | 17.5 | 21.9 | 26.9 | 35.0 | 50.0 | 174 | 0.83 | 0.86 | DN 6 |
20 | 6.28 | 13.7 | 21.9 | 27.3 | 34.2 | 42.0 | 54.7 | 78.1 | 111 | 0.86 | 0.88 | DN 6 |
22 | 7.60 | 16.5 | 26.5 | 33.1 | 41.3 | 50.9 | 66.1 | 94.5 | 92 | 0.86 | 0.88 | DN 10 |
25 | 9.82 | 21.4 | 34.2 | 42.7 | 53.4 | 65.7 | 85.4 | 122.0 | 71 | 0.87 | 0.88 | DN 10 |
27 | 11.45 | 24.9 | 39.8 | 49.8 | 62.3 | 76.6 | 99.6 | 142.3 | 61 | 0.87 | 0.88 | DN 10 |
30 | 14.14 | 30.7 | 49.2 | 61.5 | 76.9 | 94.6 | 123.0 | 175.7 | 50 | 0.88 | 0.89 | DN 10 |
36 | 20.36 | 44.3 | 70.8 | 88.6 | 110.7 | 136.2 | 177.1 | 253.0 | 34 | 0.88 | 0.89 | DN 16 |
40 | 25.13 | 54.7 | 87.5 | 109.3 | 136.7 | 168.2 | 218.7 | 312.4 | 28 | 0.89 | 0.89 | DN 16 |
44 | 30.41 | 66.1 | 105.8 | 132.3 | 165.4 | 203.5 | 264.6 | 378.0 | 23 | 0.89 | 0.89 | DN 16 |
50 | 39.27 | 85.4 | 136.7 | 170.8 | 213.5 | 262.8 | 341.6 | 488.1 | 18 | 0.89 | 0.89 | DN 16 |
60 | 56.55 | 123.0 | 196.8 | 246.0 | 307.5 | 378.4 | 492.0 | 702.8 | 12 | 0.89 | 0.90 | DN 25 |
65 | 66.37 | 144.3 | 231.0 | 288.7 | 360.9 | 444.1 | 577.4 | 824.8 | 11 | 0.89 | 0.90 | DN 25 |
Valve type: Cone valve
Note
All performance data applies to 50 Hz. If a 60 Hz motor is used, the performance will be correspondingly higher.
Abridged presentation of our complete product range. Other types on request.
Technical data for ORLITA MFS 600 single head pump 50 Hz
Plunger Ø | Theor. stroke volume | Theoretical pump capacity in l/h at strokes/min | Max. pressure | Efficiency | Standard type of valve | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
65 | 76 | 88 | 105 | 139 | 166 | 192 | ||||||
mm | ml/stroke | l/h | l/h | l/h | l/h | l/h | l/h | l/h | bar | At 100 % pressure | At 50 % pressure | |
33 | 34.21 | 133 | 157 | 180 | 215 | 286 | 342 | 395 | 400 | 0.76 | 0.83 | DN 16 |
36 | 40.72 | 158 | 187 | 214 | 256 | 340 | 407 | 470 | 393 | 0.76 | 0.83 | DN 16 |
37 | 43.01 | 167 | 197 | 226 | 270 | 359 | 430 | 496 | 372 | 0.77 | 0.83 | DN 16 |
38 | 45.36 | 176 | 208 | 238 | 285 | 379 | 453 | 523 | 353 | 0.78 | 0.83 | DN 16 |
40 | 50.27 | 195 | 231 | 264 | 316 | 420 | 502 | 580 | 318 | 0.78 | 0.84 | DN 25 |
44 | 60.82 | 237 | 279 | 320 | 382 | 508 | 608 | 702 | 263 | 0.80 | 0.85 | DN 25 |
46 | 66.48 | 259 | 305 | 349 | 418 | 556 | 664 | 767 | 241 | 0.81 | 0.85 | DN 25 |
50 | 78.54 | 305 | 360 | 413 | 493 | 656 | 784 | 906 | 204 | 0.83 | 0.86 | DN 25 |
55 | 95.03 | 370 | 436 | 499 | 597 | 794 | 949 | 1,097 | 168 | 0.84 | 0.87 | DN 32 |
60 | 113.10 | 440 | 519 | 594 | 710 | 945 | 1,130 | 1,305 | 141 | 0.84 | 0.87 | DN 32 |
65 | 132.73 | 516 | 609 | 697 | 834 | 1,109 | 1,326 | 1,532 | 121 | 0.85 | 0.87 | DN 32 |
70 | 153.94 | 599 | 706 | 809 | 967 | 1,287 | 1,538 | 1,776 | 104 | 0.86 | 0.88 | DN 40 |
75 | 176.71 | 687 | 811 | 928 | 1,110 | 1,477 | 1,765 | 2,039 | 91 | 0.86 | 0.88 | DN 40 |
80 | 201.06 | 782 | 923 | 1,056 | 1,263 | 1,680 | 2,008 | 2,320 | 80 | 0.87 | 0.88 | DN 40 |
90 | 254.47 | 990 | 1,168 | 1,337 | 1,598 | 2,127 | 2,542 | 2,936 | 63 | 0.87 | 0.88 | DN 40 |
100 | 314.16 | 1,222 | 1,442 | 1,650 | 1,973 | 2,626 | 3,138 | 51 | 0.88 | 0.89 | DN 50 | |
115 | 415.48 | 1,616 | 1,906 | 2,183 | 2,610 | 3,472 | 4,150 | 39 | 0.88 | 0.89 | DN 65 | |
125 | 490.87 | 1,909 | 2,252 | 2,579 | 3,083 | 4,102 | 4,903 | 33 | 0.89 | 0.89 | DN 65 | |
130 | 530.93 | 2,065 | 2,436 | 2,789 | 3,335 | 4,437 | 5,303 | 30 | 0.89 | 0.89 | DN 65 | |
135 | 572.56 | 2,227 | 2,627 | 3,008 | 3,597 | 4,785 | 5,719 | 28 | 0.89 | 0.89 | DN 65 | |
142 | 633.47 | 2,464 | 2,907 | 3,328 | 3,979 | 5,294 | 6,327 | 25 | 0.89 | 0.89 | DN 65 |
Valve type: Cone valve up to DN 40, plate valve as of DN 50
Note
All performance data applies to 50 Hz. If a 60 Hz motor is used, the performance will be correspondingly higher.
Abridged presentation of our complete product range. Other types on request.
Technical data for ORLITA MFS 1400 single head pump 50 Hz
Plunger Ø | Theor. stroke volume | Theoretical pump capacity in l/h at strokes/min | Max. pressure | Efficiency | Standard type of valve | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 76 | 86 | 100 | 134 | 166 | 191 | ||||||
mm | ml/stroke | l/h | l/h | l/h | l/h | l/h | l/h | l/h | bar | At 100 % pressure | At 50 % pressure | |
42 | 83.13 | 329 | 380 | 430 | 498 | 670 | 830 | 953 | 433 | 0.76 | 0.83 | DN 25 |
44 | 91.23 | 361 | 417 | 472 | 547 | 736 | 911 | 1,046 | 395 | 0.76 | 0.83 | DN 25 |
46 | 99.71 | 394 | 456 | 516 | 598 | 804 | 996 | 1,143 | 361 | 0.76 | 0.83 | DN 25 |
48 | 108.57 | 429 | 496 | 562 | 651 | 875 | 1,084 | 1,245 | 332 | 0.78 | 0.83 | DN 25 |
53 | 132.37 | 523 | 605 | 685 | 794 | 1,067 | 1,322 | 1,517 | 272 | 0.79 | 0.84 | DN 32 |
57 | 153.11 | 605 | 700 | 793 | 918 | 1,234 | 1,529 | 1,755 | 235 | 0.81 | 0.84 | DN 32 |
58 | 158.52 | 627 | 724 | 821 | 950 | 1,278 | 1,583 | 1,817 | 227 | 0.84 | 0.85 | DN 32 |
60 | 169.65 | 671 | 775 | 879 | 1,017 | 1,368 | 1,695 | 1,945 | 212 | 0.82 | 0.86 | DN 32 |
70 | 230.91 | 913 | 1,055 | 1,196 | 1,384 | 1,862 | 2,306 | 2,647 | 156 | 0.83 | 0.87 | DN 40 |
75 | 265.07 | 1,048 | 1,211 | 1,373 | 1,589 | 2,137 | 2,648 | 3,038 | 136 | 0.84 | 0.87 | DN 40 |
80 | 301.59 | 1,193 | 1,378 | 1,562 | 1,808 | 2,432 | 3,012 | 3,457 | 119 | 0.84 | 0.87 | DN 40 |
85 | 340.47 | 1,346 | 1,556 | 1,763 | 2,041 | 2,745 | 3,401 | 3,903 | 106 | 0.85 | 0.87 | DN 50 |
90 | 381.70 | 1,509 | 1,744 | 1,977 | 2,289 | 3,078 | 3,813 | 4,375 | 94 | 0.88 | 0.88 | DN 50 |
120 | 678.58 | 2,683 | 3,101 | 3,514 | 4,069 | 5,471 | 6,778 | 53 | 0.88 | 0.89 | DN 80 | |
125 | 736.31 | 2,912 | 3,364 | 3,813 | 4,415 | 5,937 | 7,355 | 49 | 0.88 | 0.89 | DN 80 | |
140 | 923.63 | 3,653 | 4,220 | 4,783 | 5,538 | 7,447 | 9,226 | 39 | 0.89 | 0.89 | DN 80 |
Valve type: Conical valve
Note
All performance data applies to 50 Hz. If a 60 Hz motor is used, the performance will be correspondingly higher.
Abridged presentation of our complete product range. Other types on request.
Downloads for Hydraulic Diaphragm Metering Pump ORLITA MF
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
Reliable capacity even at high-pressure
ORLITA MF hydraulic diaphragm metering pumps (MFS 35 to MFS 1400) with a stroke length of 15 to 60 mm provide a capacity ranging from 0 to 14,000 l/h at 450 – 30 bar. A wide range of drive versions is available, including some for use in Zone 1 or Zone 2 areas at risk from explosion with ATEX certification. The ORLITA MF product range is designed to comply with API 675. Its modular construction permits the free combination of drive units, drives and dosing heads, producing a pump for a range of different feed rates and media operating at different working pressures.
Your benefits
Excellent process safety and reliability:
- PTFE double diaphragm with integrated diaphragm rupture warning system ensures precise and low-wear operation despite high pressures
- The product chamber is hermetically separated from the hydraulic part
- Integrated hydraulic relief valve and automatic bleed valve for the hydraulic chamber
- Wear-free, valveless enforced anti-cavitation of the hydraulic leakage guarantees optimum dosing precision
- Cone valves for use as suction and/or discharge valves with minimal wear, good self-cleaning and low pressure loss (NPSHR)
Excellent flexibility:
- The modular construction allows a wide range of uses. In multiple pump systems it is possible to combine up to 6 metering units, even with different pump capacities. In single pumps the drive arrangement may be either vertical or horizontal.
Application
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Oil/ gas production (onshore/offshore)
- Refineries
- Chemical/Petrochemical industry
- Pharmaceuticals & cosmetics
- Food production
- Packaging industry (bottling pumps)
Technical Data
Technical Details
- MfS 35 (MF2a) – stroke length: 0-20 mm, rod force: 3500 N
- MfS 600 (MF5b) – stroke length: 0-40 mm, rod force: 40,000 N
- MfS 1400 (MF6a) – stroke length: 0-60 mm, rod force: 60,000 N
- Stroke length adjustment range: 0 – 100% in operation and idle
- Stroke length adjustment: manually using manual adjustment wheel and scaled display (optionally with electric actuator or control drive)
- Metering reproducibility is better than ± 1% within the 10 – 100% stroke length range under defined conditions and with correct installation (API 675)
- PTFE multi-layer diaphragm with electrical diaphragm rupture warning/signalling system via a contact
- Integrated hydraulic relief and bleed valve
- Wetted materials: Stainless steel, special designs are available on request
- A wide range of power end versions is available: Three-phase standard AC motors, motors for use in areas at risk from explosion and different flange designs for use in customer-specific motors
- Degree of protection: IP 55
- Temperature range - 40 °C to + 150 °C
- Suction lift up to 8 m
- Design in compliance with API 675 among others
Actuation of ORLITA MF, MH, PS, DR
Control drive consisting of an actuator with servo motor and integral servo controller for stroke length adjustment via a standard signal. Standard current input 0/4 – 20 mA, corresponds to stroke length 0 – 100%, switch-over for manual/automatic operation; key switch for stroke adjustment in manual mode, mechanical position display of actual stroke length value output 0/4 – 20 mA for remote display. Control drives can also be designed with bus systems, like HART, PROFIBUS®, Fieldbus Foundation ...
Variable speed motors with integrated frequency converter (identity code specification V)
Power supply 1 ph 230 V, 50/60 Hz (up to 3 kW). Externally controllable with 0/4 - 20 mA.
The following functions are integrated in the terminal box cover:
- Start/stop switch
- Switch for manual/external operation
- Potentiometer for speed control in manual mode
Speed controllers with frequency converter (identity code specification Z)
The frequency converter is accommodated in an IP 55-rated protective housing with integral control unit and main switch, suitable for max. 0.37/0.75 kW motor capacity.
Externally controllable with 0/4 - 20 mA or 0 - 10 V corresponding to 0 - 50 (60) Hz output frequency.
Integrated control unit with versatile functions, such as switching between external/internal control; frequency input using arrow keys with internal control, multilingual fault message display etc. and motor temperature monitoring (thermistor protection).
The speed controller assembly consists of a frequency converter and a variable-speed motor.
Technical data for ORLITA MFS 35 single head pump 50 Hz
Plunger Ø | Theor. stroke volume | Theoretical pump capacity in l/h at strokes/min | Max. pressure | Efficiency | Standard type of valve | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
36 | 58 | 73 | 91 | 112 | 145 | 207 | ||||||
mm | ml/stroke | l/h | l/h | l/h | l/h | l/h | l/h | l/h | bar | At 100 % pressure | At 50 % pressure | |
7 | 0.77 | 1.7 | 2.7 | 3.3 | 4.2 | 5.2 | 6.7 | 9.6 | 400 | 0.50 | 0.70 | DN 3 |
8 | 1.01 | 2.2 | 3.5 | 4.4 | 5.5 | 6.7 | 8.7 | 12.5 | 400 | 0.50 | 0.70 | DN 3 |
10 | 1.57 | 3.4 | 5.5 | 6.8 | 8.5 | 10.5 | 13.7 | 19.5 | 400 | 0.50 | 0.70 | DN 6 |
12 | 2.26 | 4.9 | 7.9 | 9.8 | 12.3 | 15.1 | 19.7 | 28.1 | 309 | 0.79 | 0.85 | DN 6 |
14 | 3.08 | 6.7 | 10.7 | 13.4 | 16.7 | 20.6 | 26.8 | 38.3 | 227 | 0.81 | 0.85 | DN 6 |
16 | 4.02 | 8.7 | 14.0 | 17.5 | 21.9 | 26.9 | 35.0 | 50.0 | 174 | 0.83 | 0.86 | DN 6 |
20 | 6.28 | 13.7 | 21.9 | 27.3 | 34.2 | 42.0 | 54.7 | 78.1 | 111 | 0.86 | 0.88 | DN 6 |
22 | 7.60 | 16.5 | 26.5 | 33.1 | 41.3 | 50.9 | 66.1 | 94.5 | 92 | 0.86 | 0.88 | DN 10 |
25 | 9.82 | 21.4 | 34.2 | 42.7 | 53.4 | 65.7 | 85.4 | 122.0 | 71 | 0.87 | 0.88 | DN 10 |
27 | 11.45 | 24.9 | 39.8 | 49.8 | 62.3 | 76.6 | 99.6 | 142.3 | 61 | 0.87 | 0.88 | DN 10 |
30 | 14.14 | 30.7 | 49.2 | 61.5 | 76.9 | 94.6 | 123.0 | 175.7 | 50 | 0.88 | 0.89 | DN 10 |
36 | 20.36 | 44.3 | 70.8 | 88.6 | 110.7 | 136.2 | 177.1 | 253.0 | 34 | 0.88 | 0.89 | DN 16 |
40 | 25.13 | 54.7 | 87.5 | 109.3 | 136.7 | 168.2 | 218.7 | 312.4 | 28 | 0.89 | 0.89 | DN 16 |
44 | 30.41 | 66.1 | 105.8 | 132.3 | 165.4 | 203.5 | 264.6 | 378.0 | 23 | 0.89 | 0.89 | DN 16 |
50 | 39.27 | 85.4 | 136.7 | 170.8 | 213.5 | 262.8 | 341.6 | 488.1 | 18 | 0.89 | 0.89 | DN 16 |
60 | 56.55 | 123.0 | 196.8 | 246.0 | 307.5 | 378.4 | 492.0 | 702.8 | 12 | 0.89 | 0.90 | DN 25 |
65 | 66.37 | 144.3 | 231.0 | 288.7 | 360.9 | 444.1 | 577.4 | 824.8 | 11 | 0.89 | 0.90 | DN 25 |
Valve type: Cone valve
Note
All performance data applies to 50 Hz. If a 60 Hz motor is used, the performance will be correspondingly higher.
Abridged presentation of our complete product range. Other types on request.
Technical data for ORLITA MFS 600 single head pump 50 Hz
Plunger Ø | Theor. stroke volume | Theoretical pump capacity in l/h at strokes/min | Max. pressure | Efficiency | Standard type of valve | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
65 | 76 | 88 | 105 | 139 | 166 | 192 | ||||||
mm | ml/stroke | l/h | l/h | l/h | l/h | l/h | l/h | l/h | bar | At 100 % pressure | At 50 % pressure | |
33 | 34.21 | 133 | 157 | 180 | 215 | 286 | 342 | 395 | 400 | 0.76 | 0.83 | DN 16 |
36 | 40.72 | 158 | 187 | 214 | 256 | 340 | 407 | 470 | 393 | 0.76 | 0.83 | DN 16 |
37 | 43.01 | 167 | 197 | 226 | 270 | 359 | 430 | 496 | 372 | 0.77 | 0.83 | DN 16 |
38 | 45.36 | 176 | 208 | 238 | 285 | 379 | 453 | 523 | 353 | 0.78 | 0.83 | DN 16 |
40 | 50.27 | 195 | 231 | 264 | 316 | 420 | 502 | 580 | 318 | 0.78 | 0.84 | DN 25 |
44 | 60.82 | 237 | 279 | 320 | 382 | 508 | 608 | 702 | 263 | 0.80 | 0.85 | DN 25 |
46 | 66.48 | 259 | 305 | 349 | 418 | 556 | 664 | 767 | 241 | 0.81 | 0.85 | DN 25 |
50 | 78.54 | 305 | 360 | 413 | 493 | 656 | 784 | 906 | 204 | 0.83 | 0.86 | DN 25 |
55 | 95.03 | 370 | 436 | 499 | 597 | 794 | 949 | 1,097 | 168 | 0.84 | 0.87 | DN 32 |
60 | 113.10 | 440 | 519 | 594 | 710 | 945 | 1,130 | 1,305 | 141 | 0.84 | 0.87 | DN 32 |
65 | 132.73 | 516 | 609 | 697 | 834 | 1,109 | 1,326 | 1,532 | 121 | 0.85 | 0.87 | DN 32 |
70 | 153.94 | 599 | 706 | 809 | 967 | 1,287 | 1,538 | 1,776 | 104 | 0.86 | 0.88 | DN 40 |
75 | 176.71 | 687 | 811 | 928 | 1,110 | 1,477 | 1,765 | 2,039 | 91 | 0.86 | 0.88 | DN 40 |
80 | 201.06 | 782 | 923 | 1,056 | 1,263 | 1,680 | 2,008 | 2,320 | 80 | 0.87 | 0.88 | DN 40 |
90 | 254.47 | 990 | 1,168 | 1,337 | 1,598 | 2,127 | 2,542 | 2,936 | 63 | 0.87 | 0.88 | DN 40 |
100 | 314.16 | 1,222 | 1,442 | 1,650 | 1,973 | 2,626 | 3,138 | 51 | 0.88 | 0.89 | DN 50 | |
115 | 415.48 | 1,616 | 1,906 | 2,183 | 2,610 | 3,472 | 4,150 | 39 | 0.88 | 0.89 | DN 65 | |
125 | 490.87 | 1,909 | 2,252 | 2,579 | 3,083 | 4,102 | 4,903 | 33 | 0.89 | 0.89 | DN 65 | |
130 | 530.93 | 2,065 | 2,436 | 2,789 | 3,335 | 4,437 | 5,303 | 30 | 0.89 | 0.89 | DN 65 | |
135 | 572.56 | 2,227 | 2,627 | 3,008 | 3,597 | 4,785 | 5,719 | 28 | 0.89 | 0.89 | DN 65 | |
142 | 633.47 | 2,464 | 2,907 | 3,328 | 3,979 | 5,294 | 6,327 | 25 | 0.89 | 0.89 | DN 65 |
Valve type: Cone valve up to DN 40, plate valve as of DN 50
Note
All performance data applies to 50 Hz. If a 60 Hz motor is used, the performance will be correspondingly higher.
Abridged presentation of our complete product range. Other types on request.
Technical data for ORLITA MFS 1400 single head pump 50 Hz
Plunger Ø | Theor. stroke volume | Theoretical pump capacity in l/h at strokes/min | Max. pressure | Efficiency | Standard type of valve | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
66 | 76 | 86 | 100 | 134 | 166 | 191 | ||||||
mm | ml/stroke | l/h | l/h | l/h | l/h | l/h | l/h | l/h | bar | At 100 % pressure | At 50 % pressure | |
42 | 83.13 | 329 | 380 | 430 | 498 | 670 | 830 | 953 | 433 | 0.76 | 0.83 | DN 25 |
44 | 91.23 | 361 | 417 | 472 | 547 | 736 | 911 | 1,046 | 395 | 0.76 | 0.83 | DN 25 |
46 | 99.71 | 394 | 456 | 516 | 598 | 804 | 996 | 1,143 | 361 | 0.76 | 0.83 | DN 25 |
48 | 108.57 | 429 | 496 | 562 | 651 | 875 | 1,084 | 1,245 | 332 | 0.78 | 0.83 | DN 25 |
53 | 132.37 | 523 | 605 | 685 | 794 | 1,067 | 1,322 | 1,517 | 272 | 0.79 | 0.84 | DN 32 |
57 | 153.11 | 605 | 700 | 793 | 918 | 1,234 | 1,529 | 1,755 | 235 | 0.81 | 0.84 | DN 32 |
58 | 158.52 | 627 | 724 | 821 | 950 | 1,278 | 1,583 | 1,817 | 227 | 0.84 | 0.85 | DN 32 |
60 | 169.65 | 671 | 775 | 879 | 1,017 | 1,368 | 1,695 | 1,945 | 212 | 0.82 | 0.86 | DN 32 |
70 | 230.91 | 913 | 1,055 | 1,196 | 1,384 | 1,862 | 2,306 | 2,647 | 156 | 0.83 | 0.87 | DN 40 |
75 | 265.07 | 1,048 | 1,211 | 1,373 | 1,589 | 2,137 | 2,648 | 3,038 | 136 | 0.84 | 0.87 | DN 40 |
80 | 301.59 | 1,193 | 1,378 | 1,562 | 1,808 | 2,432 | 3,012 | 3,457 | 119 | 0.84 | 0.87 | DN 40 |
85 | 340.47 | 1,346 | 1,556 | 1,763 | 2,041 | 2,745 | 3,401 | 3,903 | 106 | 0.85 | 0.87 | DN 50 |
90 | 381.70 | 1,509 | 1,744 | 1,977 | 2,289 | 3,078 | 3,813 | 4,375 | 94 | 0.88 | 0.88 | DN 50 |
120 | 678.58 | 2,683 | 3,101 | 3,514 | 4,069 | 5,471 | 6,778 | 53 | 0.88 | 0.89 | DN 80 | |
125 | 736.31 | 2,912 | 3,364 | 3,813 | 4,415 | 5,937 | 7,355 | 49 | 0.88 | 0.89 | DN 80 | |
140 | 923.63 | 3,653 | 4,220 | 4,783 | 5,538 | 7,447 | 9,226 | 39 | 0.89 | 0.89 | DN 80 |
Valve type: Conical valve
Note
All performance data applies to 50 Hz. If a 60 Hz motor is used, the performance will be correspondingly higher.
Abridged presentation of our complete product range. Other types on request.