Suggestions
Metering Monitor for Low-Pressure Metering Pumps

Monitoring of the individual strokes in accordance with the float principle.

Product description

Monitoring the metering process

The dosing monitor identifies the most frequent causes of metering errors, such as overpressure, cavitation The formation of small gas bubbles in a fluid. more in the glossary, air bubbles or faulty valves.

Dosing monitors are available for discharge side and suction side installation.

Your benefits

  • Detects metering errors
  • Issues alarm
  • Can be used on discharge side or suction side

Flow Control Dosing Monitor for Discharge Side Installation

Metering monitor complete with connector cable for assembly directly on the dosing head to monitor individual strokes using the float principle. The adjustment screw is used to match the partial flow flowing past the float to the set stroke volume so that an alarm is emitted if the level falls approx. 20 % below the required level. An der Dosierpumpe gamma/ X und delta® The permitted number of incompletely performed strokes can be selected between 1 to 127 on the gamma/ X and delta® metering pumps to ensure optimum adaptation to process requirements.

Suitable for metering pumps of the product ranges gamma/ X and delta® in material versions PP, NP, PV and TT.

Important: It is essential that you observe the minimum values for the stroke length. The design of the pressure stroke must be set to “fast”.

Suitable for the gamma/ X product range in material designs PP, PC, NP and TT. Complete with connector cable for assembly directly on the dosing head.

For monitoring the individual strokes based on the floating body principle. The adjustment screw is used to match the partial flow flowing past the float to the respective stroke volume so that an alarm is emitted if the level is transgressed by approx. 20%. The gamma/ L enables the permitted number of incompletely performed strokes to be selected between 1 to 127, ensuring optimum adaptation to process requirements.

Materials

Housing:PVDF
Float:PTFE-coated
Seals:FKM/EPDM

Flow Control for Discharge Side Installation

Flow ControlFor pump typeMaterialOrder no.
Size IGMXa 1602PVDF/EPDM1009229
 GMXa 1602PVDF/FKM1009335
Size IIGMXa 1604 – 0424 and DLTa 1608 – 0730PVDF/EPDM1009336
 GMXa 1604 – 0424 and DLTa 1608 – 0730PVDF/FKM1009338
Pump typeMedium operating pressureStroke length (scale division)Max. permissible operating pressureStroke length (scale division)
16028 bar> 30 %16 bar> 40%
16045 bar> 30 %16 bar> 50%
07084 bar> 30 %7 bar> 40%
10095 bar> 30 %10 bar> 40%
04142 bar> 30 %4 bar> 30%
07154 bar> 30 %7 bar> 30%
02201 bar> 30 %2 bar> 30%
04242 bar> 30 %4 bar> 30%
  • pk_1_086_2

Flow Control Dosing Monitor for Installation on Suction Side

Individual strokes are detected on the suction side, because the flow velocity is sufficiently high here. With water as the medium, the minimum stroke length is 30 % and the suction stroke is normal, HV1 or HV2.

Suitable for metering pumps of the gamma/ X and delta® product range with slow compression stroke.

Flow ControlFor pump typeMaterialOrder no.
Size IIGMXa 1604 – 0224 and DLTa 1608 – 0730PVDF/EPDM1036407
 GMXa 1604 – 0224 and DLTa 1608 – 0730PVDF/FKM1036409
Size III0450 – 0280PVDF/EPDM1036439
 0450 – 0280PVDF/FKM1036440

Downloads for Metering Monitor for Low-Pressure Metering Pumps

More in the Download Centre

0 Results
Filter by document type
Application Example / Reference (0)
Brochure / Flyer (0)
Catalogue (0)
Certificate / Declaration (0)
Data Sheet (0)
Drawing / Dimensional Drawing / 3D (0)
Exploded View / Spare Parts (0)
Material Safety Data Sheet (0)
Operating Instructions (0)
Others (0)
Press Release (0)
Publication / Article (0)
Software (0)
Wiring Diagram (0)

Selected filters:

Matching downloads

Sort by A to Z
Load more matches ...
No more matches available!

Leider haben wir kein passendes Suchergebnis gefunden.

Alle Wörter richtig geschrieben?
Mit weniger oder anderen Suchbegriffen erneut versuchen?

Please try again later

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Overview

Monitoring the metering process

The dosing monitor identifies the most frequent causes of metering errors, such as overpressure, cavitation The formation of small gas bubbles in a fluid. more in the glossary, air bubbles or faulty valves.

Dosing monitors are available for discharge side and suction side installation.

Your benefits

  • Detects metering errors
  • Issues alarm
  • Can be used on discharge side or suction side

Technical Data

Downloads

Contact us

Ralf Kiermaier

Vice President Sales and Marketing, ProMinent GmbH

»Please send us your request! We will contact you shortly.«

+49 6221 842 0  Send request   

Close Form

Your Request

Personal Information


Further product +
Attachment Maximum file size 10 MB
Upload Next file

Personal Information


Please fill in all mandatory fields.
*Mandatory fields

Check and Send


Personal Information:
Salutation
Title
Last name  
First name  
Company
Customer ID
E-mail address
Phone
Street
House no.
City  
Country
Callback Yes

Back

Matching Products

News and Events

1 2