Flushing Assemblies for Motor-Driven Metering Pumps
Flushing assemblies – also known as fittings
Product description
Cleaned, rinsed – all clear!
Flushing assemblies flush and clean the dosing head The dosing head is where the actual dosing process takes place. more in the glossary, metering line and injection valve and protect the system against deposits. They are installed on the pump's suction connector.
Your benefits
- Flushing assemblies protect against deposits
PCB Flushing Assembly
As a manual or automatic, time-controlled design. Installation, even retrospectively, on the suction connector of the metering pump. Supplied with 2 m flushing pipe and R 3/8 connection nipple. Automatic flushing equipment for the fully automatic flushing of the pump head is possible on request. Material PVC, seal FKM.
Connection | G | Order no. |
---|---|---|
DN 10 | 3/4 | 809926 |
DN 15 | 1 | 803960 |
DN 20 | 1 1/4 | 803961 |
DN 25 | 1 1/2 | 803962 |
DN 40 | 2 1/4 | 803963 |
* Caution: The product contains adhesive joints with Tangit. Please note the resistance of Tangit adhesive.
PPE Flushing Device
As a manual or automatic, time-controlled design. Installation, even retrospectively, on the suction connector of the metering pump. Supplied with 2 m flushing pipe and R 3/8 connection nipple. Automatic flushing equipment for the fully automatic flushing of the pump head is possible on request. Material PP, seal EPDM.
Connection | G | Order no. |
---|---|---|
DN 10 | 3/4 | 809917 |
DN 15 | 1 | 809919 |
DN 20 | 1 1/4 | 809921 |
DN 25 | 1 1/2 | 809923 |
Downloads for Flushing Assemblies for Motor-Driven Metering Pumps
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
Cleaned, rinsed – all clear!
Flushing assemblies flush and clean the dosing head The dosing head is where the actual dosing process takes place. more in the glossary, metering line and injection valve and protect the system against deposits. They are installed on the pump's suction connector.
Your benefits
- Flushing assemblies protect against deposits
Technical Data
PCB Flushing Assembly
As a manual or automatic, time-controlled design. Installation, even retrospectively, on the suction connector of the metering pump. Supplied with 2 m flushing pipe and R 3/8 connection nipple. Automatic flushing equipment for the fully automatic flushing of the pump head is possible on request. Material PVC, seal FKM.
Connection | G | Order no. |
---|---|---|
DN 10 | 3/4 | 809926 |
DN 15 | 1 | 803960 |
DN 20 | 1 1/4 | 803961 |
DN 25 | 1 1/2 | 803962 |
DN 40 | 2 1/4 | 803963 |
* Caution: The product contains adhesive joints with Tangit. Please note the resistance of Tangit adhesive.
PPE Flushing Device
As a manual or automatic, time-controlled design. Installation, even retrospectively, on the suction connector of the metering pump. Supplied with 2 m flushing pipe and R 3/8 connection nipple. Automatic flushing equipment for the fully automatic flushing of the pump head is possible on request. Material PP, seal EPDM.
Connection | G | Order no. |
---|---|---|
DN 10 | 3/4 | 809917 |
DN 15 | 1 | 809919 |
DN 20 | 1 1/4 | 809921 |
DN 25 | 1 1/2 | 809923 |