Metering system ULTROMAT ULPa (oscillating system)
Extraction rates from 400 to 4,000 l/h
The metering system ULTROMAT ULPa (oscillating system) is ideal for batching flocculation aids for the preparation of a ready-to-use polymer solution.
Product description
A good solution when preparing polymer solutions as flocculation aids.
ULTROMAT ULPa consists of two separate chambers which are successively filled with polymer solution, thereby ruling out the risk of product carry-over. Both liquid and powdered polymers can be processed depending on the product range.
Your benefits
- Processing of liquid polymers (0.05 - 1.0 %) and powdered polymers (0.05 - 0.5 %)
- No mixing of fresh and matured polymer
- Operator-controlled input of solvent concentration and calibration of powder feeder and liquid concentrate pump
- Gentle mixing of the polymer solution (electric stirrer)
- Pressure sensor for the measurement of the liquid level
- Version with terminal box available on request
Field of application
- Potable water treatment
- Paper production
Technical Details
Siemens S7 – 1200 compact control system and KTP 400 touch panel
- Optionally fitted with PROFIBUS® and DP/DP coupler
- Optionally fitted with PROFINET and PN/PN coupler
- Optionally fitted with Modbus TCP
Technical Data
Discharge volume | l/h | 400 | 1,000 | 2,000 | 4,000 |
---|---|---|---|---|---|
Tank contents | l | 2 x 400 | 2 x 1,000 | 2 x 2,000 | 2 x 4,000 |
Raw water feed | l/h | 1,600 | 4,000 | 8,000 | 16,000 |
Water pressure | bar | 3…5 | 3…5 | 3…5 | 3…5 |
Powdered polymer | kg/h | 0.5…11 | 0.8…18 | 3.6…55 | 4.8…110 |
Length | mm | 2,040 | 2,840 | 3,340 | 4,540 |
Width | mm | 1,253 | 1,733 | 1,918 | 2,583 |
Height | mm | 1,635 | 1,739 | 2,178 | 2,384 |
Water connection for raw water | Inch | 1 | 1 1/4 | 1 1/2 | 2 |
Discharge nozzle DN | mm | 25 | 32 | 40 | 50 |
Concentrate feed DN | mm | 15 | 15 | 20 | 20 |
Voltage / frequency | V AC / Hz | 400/50 | 400/50 | 400/50 | 400/50 |
Power uptake | kW | 2.5 | 3.2 | 5.5 | 7.0 |
Downloads for Metering system ULTROMAT ULPa (oscillating system)
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
A good solution when preparing polymer solutions as flocculation aids.
ULTROMAT ULPa consists of two separate chambers which are successively filled with polymer solution, thereby ruling out the risk of product carry-over. Both liquid and powdered polymers can be processed depending on the product range.
Your benefits
- Processing of liquid polymers (0.05 - 1.0 %) and powdered polymers (0.05 - 0.5 %)
- No mixing of fresh and matured polymer
- Operator-controlled input of solvent concentration and calibration of powder feeder and liquid concentrate pump
- Gentle mixing of the polymer solution (electric stirrer)
- Pressure sensor for the measurement of the liquid level
- Version with terminal box available on request
Application
Field of application
- Potable water treatment
- Paper production
Technical Data
Technical Details
Siemens S7 – 1200 compact control system and KTP 400 touch panel
- Optionally fitted with PROFIBUS® and DP/DP coupler
- Optionally fitted with PROFINET and PN/PN coupler
- Optionally fitted with Modbus TCP
Technical Data
Discharge volume | l/h | 400 | 1,000 | 2,000 | 4,000 |
---|---|---|---|---|---|
Tank contents | l | 2 x 400 | 2 x 1,000 | 2 x 2,000 | 2 x 4,000 |
Raw water feed | l/h | 1,600 | 4,000 | 8,000 | 16,000 |
Water pressure | bar | 3…5 | 3…5 | 3…5 | 3…5 |
Powdered polymer | kg/h | 0.5…11 | 0.8…18 | 3.6…55 | 4.8…110 |
Length | mm | 2,040 | 2,840 | 3,340 | 4,540 |
Width | mm | 1,253 | 1,733 | 1,918 | 2,583 |
Height | mm | 1,635 | 1,739 | 2,178 | 2,384 |
Water connection for raw water | Inch | 1 | 1 1/4 | 1 1/2 | 2 |
Discharge nozzle DN | mm | 25 | 32 | 40 | 50 |
Concentrate feed DN | mm | 15 | 15 | 20 | 20 |
Voltage / frequency | V AC / Hz | 400/50 | 400/50 | 400/50 | 400/50 |
Power uptake | kW | 2.5 | 3.2 | 5.5 | 7.0 |