Chlorine Dioxide System Bello Zon CDKd
7.5 – 12,000 g/h chlorine dioxide. Maximum volume of water that can be treated with metering of 0.2 ppm ClO2, depending on the size of the system: 60,000 m3/h
Chlorine dioxide system for the metering of chlorine dioxide with concentrated starting chemicals. The proven safety concept protects people and the environment. The certified yield guarantees efficient chlorine dioxide production. Bello Zon CDKd can be easily and safely integrated into any water treatment process.
Product description
Chlorine dioxide system Bello Zon CDKd treats medium to large volumes of water with concentrated chemicals.
In the chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary system there is an intrinsically safe pre-dilution station for concentrated hydrochloric acid. The consumption of hydrochloric acid can therefore be automatically adapted on-site to the individual operating conditions by means of a patent-pending process.
The system control offers impressive and user-friendly menu navigation and ensures the precise production of chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary. The chemicals are mixed perfectly in a reactor made of food-safe PVDF. You thereby benefit from maximum yield with the lowest possible consumption of chemicals and maximum operating safety. The requirements set by the Industry 4.0 standards of tomorrow are met thanks to communication via popular bus systems and our DULCONNEX Platform.
The construction and operating mode of the system also complies with all requirements of DVGW specifications W 224 and W 624 and the system is intended for operation with concentrated chemicals Bello Zon chlorite (24.5% NaClO2) and acid (25 – 37% HCl). The liquid levels of the starting chemicals can either be displayed and monitored by external liquid level sensors or by adaptive liquid level monitoring for which a patent has been applied.
Your benefits
- Cost savings through optimised acid consumption
- Communication interfaces via bus systems and DULCONNEX
- Monitoring of starting feed chemical tanks thanks to precise level indicators
- Consumption levels can be planned, enhanced availability and economical operation thanks to verification of chlorine dioxide metering and system output
- Configurable alarms and automatically generated reports: For simplified compliance with documentation obligations and to demonstrate correct operation
- Remote monitoring of systems in potentially dangerous environments
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Municipal drinking water and wastewater treatment
- Industrial process and cooling water
Technical Details
Power supply
- 100-230 V, 50/60 Hz
Inputs
- 4 analogue inputs (0/4-20 mA)
- Water flow
- Control variable
- Acid level
- Chlorite level
- 4 digital inputs
- Contact water meter 0.25-20 Hz
- Pause
- Alternative metering
- External fault
Outputs
- 1 operating signal relay
- 1 alarm signal relay
- 1 warning signal relay
- Mains output for control of the bypass pump
- 2 freely configurable analogue outputs (0/4-20 mA)
Operating substances
- 24.5% sodium chlorite, purity according to EN 938
- 25-37 % hydrochloric acid, purity according to EN 939
- Particle-free water
Degree of protection
- IP 65
Bus communication options
- Modbus TCP
- Modbus RTU
- Profibus
- Profinet
- DULCONNEX
Technical Data
Type | Chlorine dioxide metering rate (min.…max./hour, min./day)* | Max. operating pressure** | Operating temperature | Suction-side connector dimension of calibration vessels | Dimensions of the bypass connector | ||
---|---|---|---|---|---|---|---|
g/h | g/d | bar | °C | Chlorite | Acid | DN | |
* The metering figures relate to 5 or 2 bar back pressure and an ambient temperature of 20 °C. The minimum capacity/hour is based on the fact that when the system is operating at below 5 % of the nominal capacity, continuous metering is no longer possible due to the fact that the metering pumps then have a low pumping frequency. The reactor contents should be changed at least twice daily with systems that do not work continuously. Therefore, do not operate the system below the stated minimum capacity/day. | |||||||
** at an ambient temperature of 35 °C | |||||||
CDKd 150 | 7.5…150 | 56 | 8 | 10…40 | 8x5 | 6x4 | 25 |
CDKd 400 | 20…400 | 140 | 8 | 10…40 | 12x9 | 8x5 | 25 |
CDKd 900 | 45…900 | 300 | 8 | 10…40 | Pressure hose nozzle d16 | 8x5 | 25 |
CDKd 2000 | 100…2,000 | 700 | 5 | 10…40 | Pressure hose nozzle d20 | 12x9 | 40 |
CDKd 2800 | 140…2,800 | 700 | 5 | 15…40 | Pressure hose nozzle d20 | 12x9 | 40 |
CDKd 7300 | 370…7,300 | 1750 | 3 | 15…40 | Pressure hose nozzle d32 | Pressure hose nozzle d16 | 40 |
CDKd 12000 | 600…12,000 | 1750 | 2 | 18…40 | Pressure hose nozzle d32 | Pressure hose nozzle d16 | 40 |
Type | Dimensions H x W x D (approx.)* | Weight | Supply voltage 230 V** | Supply voltage 115 V** | Power consumption without bypass pump | Power consumption with bypass pump | HCl (30 %)*** | NaClO2 (24.5 %)*** |
---|---|---|---|---|---|---|---|---|
mm | kg | A | A | W | W | l/h | l/h | |
* including main system, pre-dilution and rinse valve, without bypass pump and water feed section | ||||||||
** 230 V figures with bypass pump, 115 V figures without bypass pump | ||||||||
*** Sodium chlorite (NaClO2) 24.5 %, purity in accordance with EN 938, hydrochloric acid 25-36%, purity in accordance with EN 939. The chemical consumption may vary depending on the temperature. The hydrochloric acid consumption is calculated for a concentration of 30%. Up to 25% hydrochloric acid can be saved with the aid of automatic acid adjustment. | ||||||||
CDKd 150 | 1,300 x 1,000 x 250 | 89 | 3.9 | 1.7 | 110 | 640 | 0.9 | 0.9 |
CDKd 400 | 1,675 x 900 x 460 | 119 | 3.9 | 1.8 | 160 | 690 | 2.5 | 2.5 |
CDKd 900 | 1,920 x 920 x 520 | 131 | 4.2 | 2.3 | 210 | 740 | 5.6 | 5.6 |
CDKd 2000 | 1,880 x 1,320 x 570 | 201 | - | 3.7 | 370 | - | 12.3 | 12.3 |
CDKd 2800 | 1,880 x 1,320 x 570 | 201 | - | 3.7 | 370 | - | 17.3 | 17.3 |
CDKd 7300 | 2,250 x 1,850 x 500 | 216 | - | 8.6 | 610 | - | 45.1 | 45.1 |
CDKd 12000 | 2,250 x 1,850 x 500 | 216 | - | 8.6 | 610 | - | 74.1 | 74.1 |
Ambient conditions:
Permissible relative air humidity (non-condensing) | max. 85% rel. |
Permissible ambient temperature | 40 °C |
Permissible temperature of chemicals | 10 … 35 °C |
Storage and transport temperature | -10 … +40 °C |
Degree of protection | IP 65 |
Downloads for Chlorine Dioxide System Bello Zon CDKd
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
Chlorine dioxide system Bello Zon CDKd treats medium to large volumes of water with concentrated chemicals.
In the chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary system there is an intrinsically safe pre-dilution station for concentrated hydrochloric acid. The consumption of hydrochloric acid can therefore be automatically adapted on-site to the individual operating conditions by means of a patent-pending process.
The system control offers impressive and user-friendly menu navigation and ensures the precise production of chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary. The chemicals are mixed perfectly in a reactor made of food-safe PVDF. You thereby benefit from maximum yield with the lowest possible consumption of chemicals and maximum operating safety. The requirements set by the Industry 4.0 standards of tomorrow are met thanks to communication via popular bus systems and our DULCONNEX Platform.
The construction and operating mode of the system also complies with all requirements of DVGW specifications W 224 and W 624 and the system is intended for operation with concentrated chemicals Bello Zon chlorite (24.5% NaClO2) and acid (25 – 37% HCl). The liquid levels of the starting chemicals can either be displayed and monitored by external liquid level sensors or by adaptive liquid level monitoring for which a patent has been applied.
Your benefits
- Cost savings through optimised acid consumption
- Communication interfaces via bus systems and DULCONNEX
- Monitoring of starting feed chemical tanks thanks to precise level indicators
- Consumption levels can be planned, enhanced availability and economical operation thanks to verification of chlorine dioxide metering and system output
- Configurable alarms and automatically generated reports: For simplified compliance with documentation obligations and to demonstrate correct operation
- Remote monitoring of systems in potentially dangerous environments
Application
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Municipal drinking water and wastewater treatment
- Industrial process and cooling water
Technical Data
Technical Details
Power supply
- 100-230 V, 50/60 Hz
Inputs
- 4 analogue inputs (0/4-20 mA)
- Water flow
- Control variable
- Acid level
- Chlorite level
- 4 digital inputs
- Contact water meter 0.25-20 Hz
- Pause
- Alternative metering
- External fault
Outputs
- 1 operating signal relay
- 1 alarm signal relay
- 1 warning signal relay
- Mains output for control of the bypass pump
- 2 freely configurable analogue outputs (0/4-20 mA)
Operating substances
- 24.5% sodium chlorite, purity according to EN 938
- 25-37 % hydrochloric acid, purity according to EN 939
- Particle-free water
Degree of protection
- IP 65
Bus communication options
- Modbus TCP
- Modbus RTU
- Profibus
- Profinet
- DULCONNEX
Technical Data
Type | Chlorine dioxide metering rate (min.…max./hour, min./day)* | Max. operating pressure** | Operating temperature | Suction-side connector dimension of calibration vessels | Dimensions of the bypass connector | ||
---|---|---|---|---|---|---|---|
g/h | g/d | bar | °C | Chlorite | Acid | DN | |
* The metering figures relate to 5 or 2 bar back pressure and an ambient temperature of 20 °C. The minimum capacity/hour is based on the fact that when the system is operating at below 5 % of the nominal capacity, continuous metering is no longer possible due to the fact that the metering pumps then have a low pumping frequency. The reactor contents should be changed at least twice daily with systems that do not work continuously. Therefore, do not operate the system below the stated minimum capacity/day. | |||||||
** at an ambient temperature of 35 °C | |||||||
CDKd 150 | 7.5…150 | 56 | 8 | 10…40 | 8x5 | 6x4 | 25 |
CDKd 400 | 20…400 | 140 | 8 | 10…40 | 12x9 | 8x5 | 25 |
CDKd 900 | 45…900 | 300 | 8 | 10…40 | Pressure hose nozzle d16 | 8x5 | 25 |
CDKd 2000 | 100…2,000 | 700 | 5 | 10…40 | Pressure hose nozzle d20 | 12x9 | 40 |
CDKd 2800 | 140…2,800 | 700 | 5 | 15…40 | Pressure hose nozzle d20 | 12x9 | 40 |
CDKd 7300 | 370…7,300 | 1750 | 3 | 15…40 | Pressure hose nozzle d32 | Pressure hose nozzle d16 | 40 |
CDKd 12000 | 600…12,000 | 1750 | 2 | 18…40 | Pressure hose nozzle d32 | Pressure hose nozzle d16 | 40 |
Type | Dimensions H x W x D (approx.)* | Weight | Supply voltage 230 V** | Supply voltage 115 V** | Power consumption without bypass pump | Power consumption with bypass pump | HCl (30 %)*** | NaClO2 (24.5 %)*** |
---|---|---|---|---|---|---|---|---|
mm | kg | A | A | W | W | l/h | l/h | |
* including main system, pre-dilution and rinse valve, without bypass pump and water feed section | ||||||||
** 230 V figures with bypass pump, 115 V figures without bypass pump | ||||||||
*** Sodium chlorite (NaClO2) 24.5 %, purity in accordance with EN 938, hydrochloric acid 25-36%, purity in accordance with EN 939. The chemical consumption may vary depending on the temperature. The hydrochloric acid consumption is calculated for a concentration of 30%. Up to 25% hydrochloric acid can be saved with the aid of automatic acid adjustment. | ||||||||
CDKd 150 | 1,300 x 1,000 x 250 | 89 | 3.9 | 1.7 | 110 | 640 | 0.9 | 0.9 |
CDKd 400 | 1,675 x 900 x 460 | 119 | 3.9 | 1.8 | 160 | 690 | 2.5 | 2.5 |
CDKd 900 | 1,920 x 920 x 520 | 131 | 4.2 | 2.3 | 210 | 740 | 5.6 | 5.6 |
CDKd 2000 | 1,880 x 1,320 x 570 | 201 | - | 3.7 | 370 | - | 12.3 | 12.3 |
CDKd 2800 | 1,880 x 1,320 x 570 | 201 | - | 3.7 | 370 | - | 17.3 | 17.3 |
CDKd 7300 | 2,250 x 1,850 x 500 | 216 | - | 8.6 | 610 | - | 45.1 | 45.1 |
CDKd 12000 | 2,250 x 1,850 x 500 | 216 | - | 8.6 | 610 | - | 74.1 | 74.1 |
Ambient conditions:
Permissible relative air humidity (non-condensing) | max. 85% rel. |
Permissible ambient temperature | 40 °C |
Permissible temperature of chemicals | 10 … 35 °C |
Storage and transport temperature | -10 … +40 °C |
Degree of protection | IP 65 |