Controller DULCOMETER® D1Cb/D1Cc

The controller DULCOMETER® D1Cb/D1Cc can be used for control tasks in potable water treatment, waste water treatment and many other areas. Safe, convenient and clear, thanks to the large illuminated graphic display, plain text operating menu and pH sensor monitoring.

Product description

The water analysis workhorse

The D1Cb/D1Cc controller is a 1-channel P/PID controller Controls processes automatically to ensure that the specified values (e.g. pH: acid or alkaline) are maintained even in the event of interfering influences. more in the glossary for the measured variables The physical variables to be determined by measuring. more in the glossary pH, ORP, chlorine, chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary, chlorite, ozone Significantly less environmentally harmful by-products result from the generation and use of ozone ... more in the glossary, bromine, peracetic acid Peracetic acid is particularly used in the food and beverage industry, but also for disinfection in ... more in the glossary, hydrogen peroxide Due to its complete biodegradability, hydrogen peroxide is a disinfectant and oxidising agent ... more in the glossary, fluoride, dissolved oxygen The measured variable "Dissolved oxygen" indicates the volume of gaseous oxygen physically dissolved in the aqueous phase in mg/l (ppm). more in the glossary and conductivity via mA. The sensors for pH and ORP can be directly connected via coaxial cable or using the 4-20 mA sensor input. The controller can bidirectionally control the measured variables The physical variables to be determined by measuring. more in the glossary, monitor limit values and transmit the measured value via an mA output, e.g. to a PLC Programmable Logic Controller. The mA output can optionally also be configured as an interference variable output. The controller has two pulse frequency outputs to control two metering pumps (raise and lower). Two output relays can optionally be used as limit value relays or to control motor-driven pumps or solenoid valves. An alarm relay signals the occurrence of a fault. A digital input is used to switch off the control or to process a sample water limit contact by remote control. The impact of temperature on the measurements can be provided by temperature measurement or by manual input. Menu-driven operation is possible in 20 languages.

Your benefits

  • Flexibility through free selection of variables from all measured variables
  • Safety through sensor monitoring of pH for glass breakage and line breakage
  • Flexibly upgradable, thanks to subsequent activation option of functions by means of an activation code
  • Various installation options: wall-mounted or installation in a control cabinet

Field of application

  • Measurement and control of water parameters in industrial and process water treatment plants
  • Waste water neutralisation
  • Measurement of the pH value and the disinfection parameters in potable water treatment and in the food and beverage industry
  • Measurement and control of the hygiene parameters in swimming pools
    1 2 3 4 5 6 7 8 9 10 11 12 13

    Technical Details

    • Measured variables: pH, ORP, chlorine, chlorine dioxide, chlorite, bromine, conductivity, peracetic acid, hydrogen peroxide, ozone, dissolved oxygen and fluoride
    • Method of installation, degree of protection: D1Cb wall mounting IP 65, D1Cc control panel mounting IP 54, 1/4 DIN
    • Measurement: 1 measuring channel, temperature compensation for pH
    • Control: PID controller, bidirectional controller (e.g. with pH acid and alkali)
    • Control inputs: 1 digital control input

    Technical Data

    Measuring range

    Type of connection mV:

    pH 0.00 … 14.00

    ORP - 1,000 … +1,000 mV

    Type of connection mA:

    Chlorine: 0.00...0.500/2.00/5.00/10.0/20.0/50.0/100.0 ppm

    Chlorine dioxide: 0.00...0.500/2.00/10.0/20.0 ppm

    Chlorite: 0.02...0.50/0.1...2 ppm

    Bromine: 0.02...2.0/0.1...10.0 ppm

    Ozone: 0.00...2.00 ppm

    Hydrogen peroxide, PER1 sensor : 2.0...200.0/20...2,000 ppm

    Peracetic acid: 1...20/10...200/100...2,000 mg/l

    Dissolved oxygen: 0.1...10/0.1...20 ppm

    pH: 0.00...14.00

    ORP: 0...+1,000 mV

    Conductivity: 0...20/200/1,000 mS/cm, via mA converter

    Temperature: 0...100 °C via mA converter

    Resolution

    pH: 0.01 pH

    ORP: 1 mV

    Amperometric (e. g. chlorine): 0.001/0.01 ppm, 0.01 vol.%

    Accuracy0.5% of the upper measuring range value
    Measurement input

    SN6 (input resistance > 0.5 x 1012 Ω)

    Correction variableTemperature via Pt 100/Pt 1000
    Correction range temp.0 … 100 °C
    Control characteristicP/PID control
    Control2-way control
    Signal current output

    1 x 0/4-20 mA galvanically isolated

    max. load 450 Ω

    Adjustable range and allocation (measured variable, correction variable, controlled variable)

    Control outputs

    2 pulse frequency outputs for metering pump actuation

    2 relays (limit value or pulse length)

    Alarm relay250 V ~ 3 A, 700 VA changeover contact
    Electrical connection90 – 253 V, 50/60 Hz, 15 VA
    Ambient temperature

    -5 … 50 °C

    Enclosure rating

    Wall mounting: IP 65

    Control panel version: IP 54

    Dimensions

    Wall mounting: 198 x 200 x 76 mm (WxHxD)

    Control panel version: 96 x 96 x 145 mm (WxHxD) (D1Cc)

    Weight0.8 kg

    Downloads for Controller DULCOMETER® D1Cb/D1Cc

    More in the Download Centre

    0 Results
    Filter by document type
    Application Example / Reference (0)
    Brochure / Flyer (0)
    Catalogue (0)
    Certificate / Declaration (0)
    Data Sheet (0)
    Drawing / Dimensional Drawing / 3D (0)
    Exploded View / Spare Parts (0)
    Material Safety Data Sheet (0)
    Operating Instructions (0)
    Others (0)
    Press Release (0)
    Publication / Article (0)
    Software (0)
    Wiring Diagram (0)

    Selected filters:

    Matching downloads

    Sort by A to Z
    Load more matches ...
    No more matches available!

    Leider haben wir kein passendes Suchergebnis gefunden.

    Alle Wörter richtig geschrieben?
    Mit weniger oder anderen Suchbegriffen erneut versuchen?

    Please try again later

    Service Unavailable

    The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

    Overview

    The water analysis workhorse

    The D1Cb/D1Cc controller is a 1-channel P/PID controller Controls processes automatically to ensure that the specified values (e.g. pH: acid or alkaline) are maintained even in the event of interfering influences. more in the glossary for the measured variables The physical variables to be determined by measuring. more in the glossary pH, ORP, chlorine, chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary, chlorite, ozone Significantly less environmentally harmful by-products result from the generation and use of ozone ... more in the glossary, bromine, peracetic acid Peracetic acid is particularly used in the food and beverage industry, but also for disinfection in ... more in the glossary, hydrogen peroxide Due to its complete biodegradability, hydrogen peroxide is a disinfectant and oxidising agent ... more in the glossary, fluoride, dissolved oxygen The measured variable "Dissolved oxygen" indicates the volume of gaseous oxygen physically dissolved in the aqueous phase in mg/l (ppm). more in the glossary and conductivity via mA. The sensors for pH and ORP can be directly connected via coaxial cable or using the 4-20 mA sensor input. The controller can bidirectionally control the measured variables The physical variables to be determined by measuring. more in the glossary, monitor limit values and transmit the measured value via an mA output, e.g. to a PLC Programmable Logic Controller. The mA output can optionally also be configured as an interference variable output. The controller has two pulse frequency outputs to control two metering pumps (raise and lower). Two output relays can optionally be used as limit value relays or to control motor-driven pumps or solenoid valves. An alarm relay signals the occurrence of a fault. A digital input is used to switch off the control or to process a sample water limit contact by remote control. The impact of temperature on the measurements can be provided by temperature measurement or by manual input. Menu-driven operation is possible in 20 languages.

    Your benefits

    • Flexibility through free selection of variables from all measured variables
    • Safety through sensor monitoring of pH for glass breakage and line breakage
    • Flexibly upgradable, thanks to subsequent activation option of functions by means of an activation code
    • Various installation options: wall-mounted or installation in a control cabinet

    Application

    Technical Data

    Downloads

    Contact us

    Ralf Kiermaier

    Vice President Sales and Marketing, ProMinent GmbH

    »Please send us your request! We will contact you shortly.«

    +49 6221 842 0  Send request   

    Close Form

    Your Request

    Personal Information


    Further product +
    Attachment Maximum file size 10 MB
    Upload Next file

    Personal Information


    Please fill in all mandatory fields.
    *Mandatory fields

    Check and Send


    Personal Information:
    Salutation
    Title
    Last name  
    First name  
    Company
    Customer ID
    E-mail address
    Phone
    Street
    House no.
    City  
    Country
    Callback Yes

    Back

    Matching Products

    1 2 3 4 5 6 7 8 9 10 11 12 13 14