Chlorine Dioxide System Bello Zon® CDVd

5 – 2,000 g/h of chlorine dioxide. Maximum volume of water that can be treated with metering of 0.2 ppm ClO2, depending on the size of the system: 50 - 10,000 m3/h

Chlorine dioxide system for the metering of chlorine dioxide with diluted chemicals. The certified output guarantees efficient chlorine dioxide production. The proven three-stage safety concept protects people and the environment. Bello Zon® CDVd can be easily and safely integrated into any water treatment process.

Product description

Chlorine dioxide system Bello Zon® CDVd is for the treatment of medium to large volumes of water with diluted chemicals.

The chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary system CDVd is very user-friendly. The system control offers impressive and intuitive menu guidance and ensures the precise production of chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary. The special reactor concept generates chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary safely and simply. Food-compatible PVDF is used instead of the PVC generally used in the industry. You benefit from maximum output with the lowest possible consumption of chemicals and maximum operating safety. Communication via popular bus systems, via a web server A web server is a software application executed by the DULCOMARIN® II. more in the glossary and our DULCOnneX platform fulfils all the requirements set by the Industry 4.0 standards of tomorrow.

The system meets all the requirements of the DVGW specifications W 224 and W 624 with regard to construction and operation and is intended for operation with diluted chemicals Bello Zon® chlorite (7.5% NaClO2) and acid (9% HCl). The liquid levels of the starting chemicals can either be displayed and monitored by external liquid level sensors or by adaptive liquid level monitoring for which a patent has been applied.

Your benefits

  • Maximum operating safety and purity of the CIO2 produced by PVDF reactors and three-stage safety concept
  • Communication interfaces via bus systems, web server or DULCOnneX
  • System does not stop due to empty starting feed chemical tanks, thanks to precise level indicators
  • Verification of the chlorine dioxide metering and system output: For consumption levels which can be planned and enhanced system availability
  • Automatically generated reports and alarms: For simplified compliance with documentation obligations and to demonstrate correct operation
  • Remote monitoring in potentially dangerous environments: At a safe distance, but still on-site - DULCOnneX. For more information: https://dulconnex.prominent.com/welcome.html

Field of application

  • Municipal potable water and sewage treatment
  • Industrial process and cooling water
  • Disinfection in the food and beverage industry, above all with inlet water treatment
    1 2 3 4 5 6 7 8

    Technical Details

    Power supply

    • 100-230 V, 50/60 Hz

    Inputs

    • 4 analogue inputs (0/4-20 mA)
      • Water flow
      • Control variable
      • Acid level
      • Chlorite level
    • 4 digital inputs
      • Contact water meter 0.25-20 Hz
      • Pause
      • Alternative metering
      • External fault

    Outputs

    • 1 operating signal relay
    • 1 alarm signal relay
    • 1 warning signal relay
    • Mains output for control of the bypass pump
    • 2 freely configurable analogue outputs (0/4-20 mA)

    Operating substances

    • 7.5% sodium chlorite, purity according to EN 938
    • 9% hydrochloric acid, purity according to EN 939
    • Particle-free water

    Degree of protection

    • IP 65

    Bus communication options

    • Modbus TCP / DULCOnneX
    • Modbus RTU / DULCOnneX
    • Profibus DULCOnneX
    • Profinet DULCOnneX
    TypeChlorine dioxide capacity*Max. operating pressure**Operating temp.Suction-side connector dimension of calibration vesselsDimensions of the bypass connector
     min.-max./hourmin./day  ChloriteAcid 
    g/hg/d bar°CDN
    CDVd 454.5–4516810–406x46x425
    CDVd 12012–12040810–406x46x425
    CDVd 24024–24080810–408x58x525
    CDVd 60060–600140815–4012x912x925
    CDVd 2000200–2,000468515–40Pressure hose nozzle d16Pressure hose nozzle d1640
    TypeDimensions*** H x W x D (mm)WeightPower consumption (max.) ****Power consumptionChemical consumption at 100% system capacity *****
       230 V115 Vwithout bypass pumpwith bypass pumpHCl (9 %)NaClO2 (7.5 %)
    mmkg A A W W l/h l/h
    CDVd 451,300 x 1,000 x 250553.81.61006301.11.1
    CDVd 1201,300 x 1,000 x 250553.91.61106402.92.9
    CDVd 2401,300 x 1,000 x 250593.91.81206505.75.7
    CDVd 6001,525 x 1,160 x 253844.01.922075014.314.3
    CDVd 20002,000 x 1,320 x 2901292.630047.647.6
    *The metering figures relate to 5 or 2 bar back pressure and an ambient temperature of 20 °C. The minimum capacity/per hour is based on the fact that when the plant is operating at below 5% of the nominal power, continuous metering is no longer possible due to the then low pumping frequency of the metering pumps. The reactor contents should be changed at least twice daily with systems that do not work continuously. Therefore do not operate the system below the stated minimum capacity/day.
    **at an ambient temperature of 35 °C
    ***including main system, pre-dilution and rinse valve, without bypass pump and water feed section
    ****230 V figures with bypass pump (CDVd 45-600), 115 V figures without bypass pump
    *****Sodium chlorite (NaClO2) 7.5 %, purity in accordance with EN 938, hydrochloric acid 9%, purity in accordance with EN 939. The chemical consumption may vary depending on the temperature.

    Ambient conditions:

    Permissible relative air humidity (non-condensing)max. 85% rel.
    Permissible ambient temperature40 °C
    Permissible temperature of chemicals10 … 35 °C
    Storage and transport temperature-10 … +40 °C
    Degree of protectionIP 65

    Downloads for Chlorine Dioxide System Bello Zon® CDVd

    More in the Download Centre

    0 Results
    Filter by document type
    Application Example / Reference (0)
    Brochure / Flyer (0)
    Catalogue (0)
    Certificate / Declaration (0)
    Data Sheet (0)
    Drawing / Dimensional Drawing / 3D (0)
    Exploded View / Spare Parts (0)
    Material Safety Data Sheet (0)
    Operating Instructions (0)
    Others (0)
    Press Release (0)
    Publication / Article (0)
    Software (0)
    Wiring Diagram (0)

    Selected filters:

    Matching downloads

    Sort by A to Z
    Load more matches ...
    No more matches available!

    Unfortunately, we did not find an appropriate match.

    All words written correctly?
    Search again with fewer or different search terms?

    Please try again later

    Service Unavailable

    The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

    Overview

    Chlorine dioxide system Bello Zon® CDVd is for the treatment of medium to large volumes of water with diluted chemicals.

    The chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary system CDVd is very user-friendly. The system control offers impressive and intuitive menu guidance and ensures the precise production of chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary. The special reactor concept generates chlorine dioxide Chlorine dioxide is an exceptionally reactive gas, which is not stored due to its instability ... more in the glossary safely and simply. Food-compatible PVDF is used instead of the PVC generally used in the industry. You benefit from maximum output with the lowest possible consumption of chemicals and maximum operating safety. Communication via popular bus systems, via a web server A web server is a software application executed by the DULCOMARIN® II. more in the glossary and our DULCOnneX platform fulfils all the requirements set by the Industry 4.0 standards of tomorrow.

    The system meets all the requirements of the DVGW specifications W 224 and W 624 with regard to construction and operation and is intended for operation with diluted chemicals Bello Zon® chlorite (7.5% NaClO2) and acid (9% HCl). The liquid levels of the starting chemicals can either be displayed and monitored by external liquid level sensors or by adaptive liquid level monitoring for which a patent has been applied.

    Your benefits

    • Maximum operating safety and purity of the CIO2 produced by PVDF reactors and three-stage safety concept
    • Communication interfaces via bus systems, web server or DULCOnneX
    • System does not stop due to empty starting feed chemical tanks, thanks to precise level indicators
    • Verification of the chlorine dioxide metering and system output: For consumption levels which can be planned and enhanced system availability
    • Automatically generated reports and alarms: For simplified compliance with documentation obligations and to demonstrate correct operation
    • Remote monitoring in potentially dangerous environments: At a safe distance, but still on-site - DULCOnneX. For more information: https://dulconnex.prominent.com/welcome.html

    Application

    Technical Data

    Downloads

    Contact us

    »Please send us your request! We will contact you shortly.«

    +49 6221 842 0  Send request   

    Matching Products

    1 2

    ProMinent Newsletter - customized to your industry. Register now